16

HQ21

double pump

Main operating data

If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to

apply to the maximum speed.

Oil viscosity: 25 c.St. (10W)

Temperature: 45

°

C

Inlet pressure: 0 BAR

max pressure / hydraulic fluid

BAR

250

200

150

100

50

0

Antiwear industrial

hydraulic oil

Syntetic fire

resistant fluid

max pres.

peak pres. (0,5 sec.max)

3625

2900

2175

1450

725

0

PSI

max speed / hydraulic fluid

RPM

3000

2500

2000

1500

500

0

Antiwear industrial

hydraulic oil

Syntetic fire

resistant fluid

1000

(with 0 bar in the intake pipe)

cart 12, 14

cart 17, 19, 21

max speed / intake pipe pressure

% connection factor for

the max speed

106%

104%

102%

100%

98%

96%

94%

92%

-2,9

-1,45

0

PSI

1,45

2,9

4,35

-0,2

-0,1

0

0,1

0,2

0,3

Intake pipe pressure (BAR)

0,4

5,8

flow / pressure

PSI

L / MIN

GPM

100

80

70

60

50

40

30

20

10

0

0

725

1450

2175

2900

3625

2500 rpm

1800 rpm

1500 rpm

1200 rpm

1000 rpm

600 rpm

BAR

26

20,8

15,6

10,4

0

0

50

100

150

200

250

90

5,2

power / pressure

KW

0

10

15

20

25

30

35

40

BAR

PSI

0

725

1450 2175 2900 3625

2500 rpm

1800 rpm

1500 rpm

1200 rpm

1000 rpm

600 rpm

54,4

40,8

13,6

27,2

0

HP

0

50 100 150 200 250

5

0

100

150

200

250

input torque / pressure

0

725

1450

2175

2900

3625

PSI

200

100

50

0

NM

BAR

50

150

Shaft end cartridge A02-12