11
HQ03
single pump
Cartridge A03-24
max speed / intake pipe pressure
% connection factor for
the max speed
106%
104%
102%
100%
98%
96%
94%
92%
-2,9
-1,45
0
PSI
1,45
2,9
4,35
-0,2
-0,1
0
0,1
0,2
0,3
Intake pipe pressure (BAR)
0,4
5,8
max pressure / hydraulic fluid
BAR
250
200
150
100
50
0
Antiwear industrial
hydraulic oil
Syntetic fire
resistant fluid
max pres.
peak pres. (0,5 sec.max)
3625
2900
2175
1450
725
0
PSI
Main operating data
Oil viscosity: 25 c.St. (10W)
Temperature: 45
°
C
Inlet pressure: 0 BAR
flow / pressure
PSI
L / MIN
GPM
200
160
140
120
100
80
60
40
20
0
0
725
1450
2175
2900
3625
2500 rpm
1800 rpm
1500 rpm
1200 rpm
1000 rpm
600 rpm
BAR
52
41,6
31,2
20,8
0
0
50
100
150
200
250
180
10,4
power / pressure
KW
0
10
20
30
40
50
60
70
BAR
PSI
0
725 1450 2175 2900 3625
2500 rpm
1800 rpm
1500 rpm
1200 rpm
1000 rpm
600 rpm
108,8
81,6
54,4
27,2
0
HP
0
50 100 150 200 250
0
100
150
200
250
input torque / pressure
0
725
1450
2175
2900
3625
PSI
400
200
100
0
NM
BAR
50
300
If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to
apply to the maximum speed.
max speed / hydraulic fluid
RPM
3000
2500
2000
1500
500
0
Antiwear industrial
hydraulic oil
Syntetic fire
resistant fluid
1000
(with 0 bar in the intake pipe)