TV04 single pump 24 Main operating data If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. max speed / hydraulic fluid(with 0 bar in the intake pipe) 2000 1600 1200 800 400 0 RPM Antiwear industrial hydraulic oil Syntetic fire resistant fluid Water-glycol Water-in-oil emulsion 200 600 1000 1400 1800 max speed / intake pipe pressure % correction factor for the max speed 106% 102% 100% 98% 96% 92% -2,9 -1,45 0 PSI 1,45 2,9 4,35 -0,2 -0,1 0 0,1 0,2 0,3 intake pipe pressure (BAR) 0,5 5,8 94% 104% 0,4 250 150 50 0 max pressure / hydraulic fluid BAR Antiwear industrial hydraulic oil Syntetic fire resistant fluid Syntetic fire resistant fluid max pres. peak pres. (0,5 sec.max) Water-in-oil emulsion 3625 2175 PSI 1450 725 0 100 200 2900 Sound level at 138 bar (2000 psi) 70 66 62 dB(A) 1200 rpm 1500 rpm 1800 rpm 60 64 68 speed