2013-08 / 04 Catalogue LM1 - 008 UK Page 8 Edition Control options Integrated control: M manual reversal of sense of direction with standstill in centre position Integrated control: MP manual / pneumatic reversal of sense of direction with standstill in centre position Function: Reversal of sense of direction with motor standstill in centre position via manual lever. The switch position engages. At the measuring connections 5 (MA) and 6 (MB ), the operating pressure applied to the rotors may be tapped for measuring and control purposes. Function: Reversal of sense of direction with motor standstill in centre position via manual lever. The switch position engages. Override by the pneumatic remote control via connections 3/4. By default, each of connections 3/4 has a vent plug for manual lever operation. In case of pneumatic remote control, one 3/8“ quick-action vent valve should be installed at the connections 3/4. The control pressure should not fall below 5.0 bar. At the measuring connections 5 (MA ) and 6 (MB ), the operating pressure applied to the rotors may be tapped for measuring and control purposes. Oiler Sieve filter gasket (Mesh 3mm) Internal housing Speed limiter Hand- reversal (*6) (*5) 2 1 Pneumatic connections: 1 : Air inlet DN50, G2“ 2 : Air outlet - Silencer installation, optional *5/6 : Measuring connection (optional - also available as a special version) Oiler Sieve filter gasket (Mesh 3mm) Internal housing Speed limiter Pneumatic remote control Hand- reversal (*6) (*5) 4 3 2 1 Pneumatic connections: 1 : Air inlet DN50, G2“ 2 : Air outlet - Silencer installation, optional 3/4 : Control connection G 3/8“ *5/6 : Measuring connection (optional - also available as a special version)
RkJQdWJsaXNoZXIy NzQyNjQ=