DMO series pneumatic motors available from jbj Techniques Limited

2013-08/ 04 Catalogue LM1 - 009 UK Page 12 Edition Maintenance unit with filter, governor and lubricator schematic symbol maintenance unit filter, governor, lubricator flange design thread design flowdirection typ order-no. DN nom. size A (mm) B (mm) C (mm) nom. pressure bar circulatory m3/min oil volume cm3 weight (kg) C630-08FRL-W-D 20.9990.0588 25 / G1 400 267 197 16 9 500 7,2 C630-12FRL-W-D 20.9990.0589 40 / G11/2 419 286 206 16 11 500 9,6 C630-16FRL-W-D 20.9990.0566 50 / G2 485 425 356 16 28 500 16,1 typ order-no. DN nom. size A (mm) B (mm) C (mm) nom. pressure bar circulatory m3/min oil volume cm3 weight (kg) C630-08FRL-W-D-F 20.9990.0590 25 / G1 520 267 197 16 9 1000 8,2 C630-12FRL-W-D-F 20.9990.0591 40 / G11/2 559 286 206 16 11 1000 10,6 C630-16FRL-W-D-F 20.9990.0592 50 / G2 661 425 356 16 28 1000 17,1 Function : The inlett pressure p1 must be at least 2 bar higher than the outlet pressure p2. Material : casing - zinc diecasting oiler and filter - zinc diecasting with level indicator Draining : manually hand- drain Temperatur range : 0 to 70° C Filter element- mesh aperture : 40 μm Mounting position : horizontal flowdirection