5 #DriveLineHarmony www.jbj.co.uk/pneumatic-starters.html Pneumatic Starters PS 24/20 Pneumatic Starter PS 24/20 Characteristic curves, calculation of air consumption Approximate calculation of air consumption for a starting operation Duration of starting procedure: 3 sec. Starter pinion speed: 1500 rpm, at ignition speed of motor Operating pressure at starter p : 6 bar e 3 Air consumption of starter at 1500 rpm and p 6 bar: 10.3 m /min, (diagram) e 3 Air consumption per start: 10.3 *3 ΔV = = 0,52 m 60 *Since a constant speed of 1500 rpm over 3 sec. was expected, savings in compressed air for the run-up phase from 0 to 1500 rpm is not taken into consideration. Approximate determination of size of air reservoir Number of starting procedures: 3 Pressure in reservoir (assumed): 30 bar Usable pressure drop: 24 bar 3 Total air consumption: 1.56 Nm 3 Size of air reservoir: 0.065 m