Mechanical-Power-Take-Off-selection-guide

The following general formula should be used for determining the actual applied load: L = Actual applied load kg (lbs) N = Shaft speed (rpm) D = Pitch diameter mm (inches) of pulley, etc. F = Load factor, 1.0 for chain or gear drive, 1.5 for timing belts, 2.5 for all V belts, 3.5 for flat belts. LF = 2.1 for reciprocating compressors and other severe shock drives and 1.8 for large inertia type drives (i.e. Crushers, chippers, planers, etc.) Compound Drives and Power Engaged Power Take-Off applications must have written factory review. IB321P M2156B RPM PTO Model 25.4 (1.0) 50.8 (2.0) 76.2 (3.0) 101.6 (4.0) 127.0 (5.0) X Distance, mm (in) – see diagram IP321P – Allowable Side Load, kg (lbs) Standard IB Series Inline Clutch IB321P Series www.jbj.co.uk/mechanical-power-conversion.html #DriveLineHarmony Dimensions are in mm (inches) 1000 152.4 (6.0) 177.8 (7.0) IB321P 1200 1800 2000 (Imperial) L = x F x LF 126,000 x HP N x D (metric) L = x F x LF 1945010 x kW N x D 50 2200 7391 (16295) 6970 (15432) 6199 (13666) 6007 (13244) 5835 (12863) 7108 (15670) 6731 (14840) 5961 (13142) 5777 (12737) 5610 (12369) 6846 (15092) 6483 (14292) 5741 (12657) 5564 (12266) 5404 (11913) 6185 (13635) 5536 (12206) 5366 (11829) 5211 (11488) 5397 (11898) 5346 (11786) 5181 (11423) 5399 (11903) 4787 (10554) 4300 (9482)