250 200 150 100 50 0 max pressure / hydraulic fluid BAR Antiwear industrial hydraulic oil Syntetic fire resistant fluid max pres. 3625 peak pres. (0,5 sec.max) 2900 2175 PSI 1450 725 0 max speed / hydraulic fluid (with 0 bar in the intake pipe) If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. max speed / intake pipe pressure % correction factor for the max speed 106% 104% 102% 100% 98% 96% 94% 92% -2,9 -1,45 0 PSI 1,45 2,9 4,35 -0,2 -0,1 0 0,1 0,2 0,3 Intake pipe pressure (BAR) 0,4 5,8 Main operating data 3000 2500 2000 1500 1000 500 0 RPM Olio min. con addittivi antiusura Fluido sintetico Vane Pumps Double Pump HQ31 Series 28 #DriveLineHarmony www.jbj.co.uk/vane-pumps.html H Y D R A U L I C S