250 200 150 100 50 0 max pressure / hydraulic fluid BAR Antiwear industrial hydraulic oil Syntetic fire resistant fluid max pres. 3625 peak pres. (0,5 sec.max) 2900 2175 PSI 1450 725 0 max speed / hydraulic fluid (with 0 bar in the intake pipe) 3000 2500 2000 1500 1000 500 0 RPM Antiwear industrial hydraulic oil Syntetic fire resistant fluid cart. 17 19 21 cart. 12 , 14 If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. max speed / intake pipe pressure % correction factor for the max speed 106% 104% 102% 100% 98% 96% 94% 92% -2,9 -1,45 0 PSI 1,45 2,9 4,35 -0,2 -0,1 0 0,1 0,2 0,3 Intake pipe pressure (BAR) 0,4 5,8 Main operating data Vane Pumps Single Pump HQ02 Series 2 #DriveLineHarmony www.jbj.co.uk/vane-pumps.html H Y D R A U L I C S
RkJQdWJsaXNoZXIy NzQyNjQ=