Main operating data If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. Oil viscosity: 25 c.St. (10W) Temperature: 45°C Inlet pressure: 0 BAR max pressure / hydraulic fluid BAR 250 200 150 100 50 0 Antiwear industrial hydraulic oil Syntetic fire resistant fluid max pres. 3625 peak pres. (0,5 sec.max) 2900 2175 1450 725 0 PSI max speed / hydraulic fluid RPM 3000 2500 2000 1500 500 0 Antiwear industrial hydraulic oil Syntetic fire resistant fluid 1000 (with 0 bar in the intake pipe) cart 12, 14 cart 17, 19, 21 max speed / intake pipe pressure % connection factor for the max speed 106% 104% 102% 100% 98% 96% 94% 92% -2,9 -1,45 0 PSI 1,45 2,9 4,35 -0,2 -0,1 0 0,1 0,2 0,3 Intake pipe pressure (BAR) 0,4 5,8 flow / pressure PSI L / MIN GPM 100 80 70 60 50 40 30 20 10 0 725 1450 2175 2900 0 3625 2500 rpm 1800 rpm 1500 rpm 1200 rpm 1000 rpm 600 rpm BAR 26 20,8 15,6 10,4 0 0 50 100 150 200 250 power / pressure 90 5,2 KW 0 10 15 20 25 30 35 PSI 0 725 1450 2175 2900 3625 40 BAR 2500 rpm 1800 rpm 1500 rpm 1200 rpm 1000 rpm 600 rpm 54,4 40,8 13,6 27,2 0 HP 0 50 100 150 200 250 5 0 100 input torque / pressure 0 725 1450 150 200 250 PSI 2175 2900 3625 200 100 50 0 NM 50 BAR 150 Shaft end cartridge A02-12 Vane Pumps Double Pump HQ21 Series 14 #DriveLineHarmony www.jbj.co.uk/vane-pumps.html H Y D R A U L I C S