HQ series fixed displacement hydraulic vane pumps available from jbj Techniques Limited

Main operating data If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed. Oil viscosity: 25 c.St. (10W) Temperature: 45°C Inlet pressure: 0 BAR max pressure / hydraulic fluid BAR 250 200 150 100 50 0 Antiwear industrial hydraulic oil Syntetic fire resistant fluid max pres. 3625 peak pres. (0,5 sec.max) 2900 2175 1450 725 0 PSI max speed / hydraulic fluid RPM 3000 2500 2000 1500 500 0 Antiwear industrial hydraulic oil Syntetic fire resistant fluid 1000 (with 0 bar in the intake pipe) cart 12, 14 cart 17, 19, 21 max speed / intake pipe pressure % connection factor for the max speed 106% 104% 102% 100% 98% 96% 94% 92% -2,9 -1,45 0 PSI 1,45 2,9 4,35 -0,2 -0,1 0 0,1 0,2 0,3 Intake pipe pressure (BAR) 0,4 5,8 flow / pressure PSI L / MIN GPM 100 80 70 60 50 40 30 20 10 0 725 1450 2175 2900 0 3625 2500 rpm 1800 rpm 1500 rpm 1200 rpm 1000 rpm 600 rpm BAR 26 20,8 15,6 10,4 0 0 50 100 150 200 250 power / pressure 90 5,2 KW 0 10 15 20 25 30 35 PSI 0 725 1450 2175 2900 3625 40 BAR 2500 rpm 1800 rpm 1500 rpm 1200 rpm 1000 rpm 600 rpm 54,4 40,8 13,6 27,2 0 HP 0 50 100 150 200 250 5 0 100 input torque / pressure 0 725 1450 150 200 250 PSI 2175 2900 3625 200 100 50 0 NM 50 BAR 150 Shaft end cartridge A02-12 Vane Pumps Double Pump HQ21 Series 14 #DriveLineHarmony www.jbj.co.uk/vane-pumps.html H Y D R A U L I C S