ELIKA® low noise, high efficiency gear pumps available from jbj Techniques Limited

® Low Noise, Low Pulsation Gear Pump Elika ELI2BK7 Series Inlet Outlet Pump type Displacement Flow at 1500 rpm Operating pressures Rotational speed Noise at 1500 rpm Dimensions P1 max. continuous P2 max intermittent P3 max peak min. speed max. speed on recirculation at P1 L M D H d h [cm3/rev] [l/min] [bar] [bar] [bar] [rpm] [rpm] [dBA] [dBA] [mm] [mm] [mm] [mm] [mm] [mm] ELI2BK7-D-7.0 7 10.5 280 295 310 300 4000 47 51 45.2 93.2 15 40 15 35 ELI2BK7-D-8.2 8.2 12.3 280 295 310 300 4000 47 52 46.2 95.2 15 40 15 35 ELI2-BK7-D-9.6 9.6 14.5 280 295 310 300 4000 48 54 47.5 97.7 15 40 15 35 ELI2BK7-D-11.4 11.4 17.1 280 295 310 300 4000 48 55 49 100.7 20 40 15 35 ELI2BK7-D-14.0 14 21 260 275 290 300 4000 49 55 51.2 105.2 20 40 15 35 ELI2BK7-D-16.1 16.1 24.1 260 275 290 300 4000 49 56 53 108.7 20 40 15 35 ELI2BK7-D-17.8 17.8 26.7 260 275 290 300 4000 49 57 54.5 111.7 20 40 15 35 ELI2BK7-D-21.0 21 31.5 230 245 260 200 3500 49 57 57.2 117.2 20 40 15 35 ELI2BK7-D-23.7 23.7 35.5 230 245 260 200 3200 50 57 59.5 121.7 20 40 15 35 ELI2BK7-D-25.7 25.7 38.6 210 225 240 200 3000 50 57 61.2 125.2 20 40 15 35 ELI2BK7-D-28.0 28 42.1 200 215 230 200 2600 50 58 63.2 129.2 20 40 15 35 ELI2BK7-D-35.0 35.1 52.6 150 165 180 200 2200 50 58 69.2 141.2 20 40 15 35 Standard ports: M6 threads depth 13 mm. To mount the pump: n°2 M10 screws with a torque wrench setting fixed at 46 ±4 Nm. Please strictly follow assembly and use instructions given in this catalogue for top performance and longer life of the ELI Marzocchi series. It is also very important to equip the hydraulic system with a proper filtering unit. 19 www.jbj.co.uk/ELIKA_gearpumps.html #DriveLineHarmony

RkJQdWJsaXNoZXIy NzQyNjQ=