WM600 Series Hydraulic Gear Motor Case Drain 12 www.jbj.co.uk/concentric-ab-uk-distributor.html#range Installation Information FLUIDS: Most premium grade petroleum base fluids can be used with WM600 Motors. Optimum operating viscosity is 16-63 cSt (80-288 SSU) at maximum rated speed. Minimum operating viscosity is 10 cSt (59 SSU). Maximum operating viscosity is 750 cSt (3409 SSU). Maximum cold start viscosity is 2000 cSt (9091SSU). Contact Concentric for additional information regarding the W600 performance using other fluids. OPERATING TEMPERATURES: Fluid temperature range (Mineral Oil): Max. 93oC (200oF) continuous and Max. 105°C (221°F) intermittent. FILTRATION: Proper filtration is critical to the trouble free operating of any hydraulic system. For optimum motor life at maximum pressure ISO 4406/1986 (Code 18/14) is recommended. A 10-micron filter sized to accommodate full system return flow is recommended for most operating environments. Valve Options www.jbj.co.uk/gear-motors.html