BD series high pressure vane pumps available from jbj Techniques Limited

50 0 150 100 250 200 BAR 0 1000 2000 3000 4000 P.S.I. intermittent continuos 300 intermittent continuos intermittent continuos Antiwear oil Water in oil emulsion Antiwear oil Water in oil emulsion Water glycol / Syntetic fluid P1 Water glycol / Syntetic fluid 50 0 150 100 250 200 BAR 0 1000 2000 3000 4000 P.S.I. intermittent continuos 300 14 - 45 50 intermittent continuos intermittent continuos P2 500 0 1500 1000 2500 2000 R.P.M. mineral oil water glycol syntetic fluid 3000 water in oil emulsion Speed r.p.m. 45 50 52 62 66 72 2200 1.00 1.00 1.00 1.00 1.09 1.05 2100 0.90 0.90 0.90 0.95 1.00 1.00 1800 0.80 0.80 0.80 0.85 0.95 0.85 1500 0.80 0.80 0.80 0.80 0.85 0.85 P1 1200 0.80 0.80 0.80 0.80 0.85 0.85 Speed r.p.m. from 14 to 20 24 28 31 35 38 42 45 50 2500 1.00 1.10 1.18 1.23 1.29 1.29 - - - 2300 0.95 0.95 1.00 1.00 1.02 1.05 1.08 - - 2200 0.88 0.88 0.92 0.95 0.98 1.00 1.02 1.05 1.09 2100 0.80 0.82 0.85 0.90 0.92 0.95 0.95 0.98 1.02 1800 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.85 0.85 1500 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 P2 1200 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 Main operating data max pressure / fluid type max speed / fluid type min. allowable inlet pressure / rotation speed (abs. bar)* * measured inside the inlet flange; with petroleum base fluid (visc. 10 to 65 cSt.). Multiply the abs. pressure by 1.25 when using water-glycol or “water in oil emulsion”, by 1.35 with synthetic fluids, and by 1.1 with ester or rapeseed base. Hydraulic Vane Pumps High Pressure Hydraulic Vane Pumps BD54 Series 47 www.jbj.co.uk/vane-pumps.html #DriveLineHarmony