Air blast coolers available from jbj Techniques Limited

82 Cooling & Heat Exchange GA Series Autonomous (off-line) Coolers MODEL Oil Flow Cooling Capacity Cooling Capacity Poles/Power Motor V/Hz Max. Amp GA302V400A 9 litres/min 4.8 KW DT40°C 0.12 kW/°C 4P / 0.75 kW 400 / 50 2.5 GA302V400A25L 25 litres/min 6.3 / 6.7 KW DT40°C 0.15/0.16 kW/°C 4P / 0.65/1 kW 400 / 50 to 460 / 60 2.2/3.1 GA303V400A 9 litres/min 5.4 KW KW DT40°C 0.135 kW/°C 4P / 0.75 kW 400 / 50 2.5 GA303V400A25L 25 litres/min 6.9 / 7.5 KW DT40°C 0.17 / 0.19 kW/°C 4P / 0.65/1 kW 400 / 50 to 460 / 60 2.2 / 3.1 GA403V400A 9 litres/min 7.8 KW DT40°C 0.195 kW/°C 4P / 0.75 kW 400 / 50 2.5 GA403V400A25L 25 litres/min 11.8 / 12.5 KW DT40°C 0.29 / 0.31 kW/°C 4P / 0.65/1 kW 400 / 50 to 460 / 60 2.2 / 3.1 GA403V400A50L 50 litres/min 13.8 KW DT40°C 0.345 kW/°C 4P / 2 kW 400 / 50 5 GA405V400A 9 litres/min 9.2 KW DT40°C 0.23 kW/°C 4P / 0.75 kW 400 / 50 2.5 GA405V400A25L 25 litres/min 15.4 / 17 KW DT40°C 0.38 / 0.425 kW/°C 4P / 0.65/1 kW 400 / 50 to 460 / 60 2.2 / 3.1 GA405V400A50L 50 litres/min 19 KW DT40°C 0.475 kW/°C 4P / 2 kW 400 / 50 5 GA453V400A 9 litres/min 8.4 KW DT40°C 0.21 kW/°C 4P / 0.75 kW 400 / 50 2.5 GA453V400A25L 25 litres/min 14 / 15 KW DT40°C 0.35 / 0.375 kW/°C 4P / 0.65/1 kW 400 / 50 to 460 / 60 2.2 / 3.1 GA453V400A50L 50 litres/min 16 KW DT40°C 0.4 kW/°C 4P / 2 kW 400 / 50 5 GA455V400A 9 litres/min 10 KW DT40°C 0.25 kW/°C 4P / 0.75 kW 400 / 50 3.68 GA455V400A25L 25 litres/min 18 / 19.5 KW DT40°C 0.45 / 0.487 kW/°C 4P / 0.65/1 kW 400 / 50 to 460 / 60 2.2 / 3.1 GA455V400A50L 50 litres/min 22 KW DT40°C 0.55 kW/°C 4P / 2 kW 400 / 50 5 GA455V400A80L 80 litres/min 25.5 / 28 KW DT40°C 0.637 / 0.7 kW/°C 4P / 1.5 kW 400 / 50 to 480 / 60 3.68 GA505V400A25L 25 litres/min 21 / 22.5 KW DT40°C 0.525 / 0.562 kW/°C 4P / 0.65/1 kW 400 / 50 to 460 / 60 2.2 / 3.1 GA505V400A50L 50 litres/min 26 KW DT40°C 0.665 kW/°C 4P / 2 kW 400 / 50 5 GA505V400A80L 80 litres/min 30 / 33 KW DT40°C 0.75 / 0.825 kW/°C 4P / 1.5 kW 400 / 50 to 480 / 60 3.68 GA655V400A80L 80 litres/min 48 / 50 KW DT40°C 1.2 / 1.25 kW/°C 4P / 3 kW 400 / 50 to 480 / 60 6.49 GA907V400A 440 litres/min 148.8 KW DT40°C 3.7 kW/°C 4P / 5.5 kW 230-400/50 to 280-480/60 11 The GA products are used in circuits where an exchanger cannot be installed on the hydraulic circuit return line due to pressure spikes and high flows in the circuit. These off-line cooling systems include an aluminium heat exchanger, an electric motor that operates a gear pump and a fan. Material: Aluminium Working pressure: 6 bar

RkJQdWJsaXNoZXIy NzQyNjQ=