6 www.jbj.co.uk/hydraulic-motors.html #DriveLineHarmony LSHT Hydraulic Motors AE3 - AE5 Technical Specifications & Dimensions Max. intermittent power P . kW 3.8 3.8 3.8 interm Max. continuous power P . kW 3.2 3.2 3.2 cont Mass m kg 3.4 3.4 3.4 Temperature range of pressure medium Θ °C -30 to +80 2 Viscosity u mm /s 18 till 1000, recommended: 30 till 50 2 Mass moment of intertia J kgm 0.000045 0.000045 0.000045 Operating speed range n rpm 10-5250 5-3750 3-3000 2 All parameters at u = 32 mm /s; Θ = 40°C; outlet = pressureless Nominal size NS 3 4 5 Max. torque T . Nm 10.25 14.25 18.5 max 3 Displacement V cm /rev 2.859 4.003 5.146 g Theor. specific torque T . Nm/bar 0.046 0.064 0.082 spec.theor Average specific torque T . Nm/bar 0.041 0.057 0.074 spec.aver Continuous torque T . Nm 8.6 12 15.5 cont Inlet pressure, max. cont. p . bar 210 210 210 cont max. p . bar 250 250 250 max peak p bar 315 315 315 peak Total pressure p bar 315 315 315 total Leakage pressure, max. p . bar 1.5 1.5 1.5 leak Example of type designation: AE (3 till 5) ZB5FN Example of type designation: AE (3 till 5) ZBFN P . = Power, which may be demanded temporarily (max. 10% duty cycle / hour). interm p = peak pressure, where the components remain safe in function. peak P . = Continuous power (at maximal 10 bar outlet pressure). Motor flushing must be carried out above P . cont cont p . = maximal admissible operating pressure at limitation P . and max. 10% duty cycle / hour max interm p = maximum permissible pressure combined out of inlet and outlet pressure. total p . = admissible continuous pressure at limitation to p cont cont
RkJQdWJsaXNoZXIy NzQyNjQ=