28 www.jbj.co.uk/hydraulic-motors.html #DriveLineHarmony LSHT Hydraulic Motors AE22 - AE45 Technical Specifications & Dimensions Inlet pressure, max. cont. p . bar 210 210 210 210 cont Leakage pressure, max. p . bar 1.5 1.5 1.5 1.5 leak Theor. specific torque T . Nm/bar 0.358 0.501 0.645 0.716 spec.theor Total pressure p bar 315 315 315 315 total 2 All parameters at u = 32 mm /s; Θ = 40°C; outlet = pressureless 3 Displacement V cm /rev 22.501 31.501 40.502 45.002 g Operating speed range n rpm 10-2000 5-2000 3-2000 10-2000 Max. intermittent power P . kW 11.0 15.0 19.0 21.5 interm Average specific torque T . Nm/bar 0.322 0.451 0.580 0.645 spec.aver peak p bar 315 315 315 315 peak 2 Mass moment of intertia J kgm 0.00195 0.00195 0.00195 0.00195 max. p . bar 250 250 250 250 max Temperature range of pressure medium Θ °C -30 to +80 Max. torque T . Nm 81 113 145 161 max Nominal size NS 22 32 40 45 2 Viscosity u mm /s 18 till 1000, recommended: 30 till 50 Continuous torque T . Nm 68 95 122 135 cont Max. continuous power P . kW 9.0 12.5 16.0 18.0 cont Mass m kg 22 22 22 22 p . = admissible continuous pressure at limitation to p cont cont p . = maximal admissible operating pressure at limitation P . and max. 10% duty cycle / hour max interm p = peak pressure, where the components remain safe in function. peak P . = Continuous power (at maximal 10 bar outlet pressure). Motor flushing must be carried out above P . cont cont P . = Power, which may be demanded temporarily (max. 10% duty cycle / hour). interm p = maximum permissible pressure combined out of inlet and outlet pressure. total Example of type designation: AE (22 till 45) ZAN Example of type designation: AE (22 till 45) ZA1FN
RkJQdWJsaXNoZXIy NzQyNjQ=